Wind loads on glass railings: everything you need to know
What do Spanish regulations say about wind action?
- Variable actions
- Imposed loads
- Actions on railings and partition elements
- Wind
- Thermal actions
- Snow
- Wind action
- Dynamic wind pressure
- Exposure coefficient
- External pressure coefficients
The Spanish Technical Building Code (CTE), through Basic Document DB SE-AE, Actions on Structures, establishes the criteria for assessing wind action on building elements.
Specifically, Section 3.3, which addresses wind action, states that for the local analysis of façade and building envelope elements, such as window and door frames and glazing, wind action must be determined from the pressures acting at each point, applying the wind pressure coefficients defined in Annex D.3.
Applying these coefficients requires consideration of several factors, including:
Geographical location and basic wind speed: Identification of the applicable wind zone under the CTE and its corresponding basic reference wind speed.
Terrain roughness: Exposure coefficients influenced by the surrounding topography, distinguishing between densely developed urban environments and open areas or seafront locations.
Installation height and position within the building: Pressure variations and increasing wind speeds depending on height above ground level and the precise location of each railing section.
Effective area of the exposed surface: The surface area considered in the analysis can influence the wind loads acting on the system.
Since wind is classified as a variable action and railings are subject to an ultimate limit state verification of resistance, the partial safety factor of 1.5 for variable actions, specified in Table 4.1 of the CTE DB-SE Structural Safety, must be applied.
When wind action acts in the same direction as the horizontal force, as occurs under wind suction conditions, both actions must be considered in combination when verifying structural resistance. In this case, the partial safety factor of 1.5 is applied to the variable actions, together with a combination factor of 0.6 for wind action, as established in Table 4.2 of the CTE DB-SE Structural Safety, which sets out the combination factors for variable actions.
Consequently, a railing may meet the resistance requirements for the horizontal load associated with its occupancy category yet fail to satisfy the requirements when the combined effects of wind action are considered. This highlights the importance of accounting for both actions when calculating and dimensioning the system to ensure structural safety and compliance with current regulations.
Wind is one of the actions that can influence the design and safety of glass railings. Its effects depend on factors such as the building’s location, installation height and surrounding environment. Understanding how wind loads are determined and what requirements are established by the Spanish Technical Building Code (CTE) is therefore essential to ensuring the safety of these protective systems.
What happens if wind action is not taken into account?
Limiting the structural verification of a glass railing solely to the horizontal load associated with its occupancy category can result in inadequate structural design, particularly in outdoor installations. This becomes even more critical in locations subject to demanding wind exposure conditions, such as high-rise buildings, coastal areas and particularly exposed sites.
Failing to consider these loads can compromise the strength and stability of the entire system, including the glass and its fixing components. Correctly assessing wind action is therefore essential to ensuring that glass railings meet the safety requirements established by the CTE.
In practical terms, failing to account for wind action when designing a glass railing can have technical, legal and safety implications.
For the project management and supervision team
It may result in non-compliance with regulatory requirements and lead to liability arising from inadequate supervision or approval of the installed solution.
For users
It may compromise the railing’s strength and stability, putting the safety of those who rely on this protective element at risk.

A real-world example illustrating the importance of wind loads on glass railings
The Intempo Residential Sky Resort building in Benidorm provides a clear example of why wind action must be considered when designing glass railings.
With two towers reaching approximately 200 metres in height, this project required high-performance railing solutions capable of withstanding both horizontal loads associated with occupancy and the significant forces generated by wind.
Our GlassFit SV-1802 Side profile system for glass railings was installed on the terraces of the central diamond-shaped structure. Its selection was influenced by the project’s structural resistance requirements and the need to accommodate particularly thick, high-strength glass panels.
Comenza’s Technical Office assessed the mechanical performance of the system through Finite Element Method (FEM) simulations. The team also calculated the anchoring requirements and carried out the preliminary design of the steel fixing plate. As part of this process, wind loads were verified at a height of more than 50 storeys, with wind pressures reaching 3.5 kN/m², compared with a horizontal load of 1.6 kN/m.
In high-rise buildings and particularly exposed locations, wind action can become a determining factor in ensuring the strength, stability and safety of the entire railing system.
Comenza provides expert assistance through its online technical support service
At Comenza, we not only develop railing systems tested to meet regulatory requirements; we also provide professionals with a dedicated online technical support service. Our team can assist you with:
Feasibility and regulatory assessments: Identifying the most suitable system, ensuring compliance with the CTE (SE-AE, SUA-1) and providing the necessary technical documentation and test reports.
Structural calculation reports and FEM analysis: Verification of applied loads, glass stresses and anchor design through finite element simulations.
Construction details and BIM: BIM families and construction details tailored to on-site requirements, ensuring seamless integration into the building.
Online technical consultations: Drawing reviews, preliminary wind load calculations and verification of construction junctions with specialist architects from our Technical Office.